ES-1 METAL COPING, EDGE METAL AND GT-1 GUTTERS

True Metal Supply is an NRCA-authorized fabricator. We fabricate specific copings, fascia, edge metal and external gutters for low-slope roofs in Knoxville, Tennessee, to the details in NRCA's UL certifications for ANSI/SPRI/FM 4435/ES-1 and ANSI/SPRI GT-1.

AT A GLANCE

EDGE METAL STANDARD

ANSI/SPRI/FM 4435/ES-1

GUTTER STANDARD

ANSI/SPRI GT-1

TESTED DETAILS

50 Edge Metal, 5 Gutter

MANUFACTURED WITH

AMERICAN STEEL

ES-1

WHAT IS ES-1?

ES-1 is the wind test standard for edge systems on low-slope roofs. Its full name is ANSI/SPRI/FM 4435/ES-1. It covers perimeter edge metal such as fascia and coping, and it shows whether those parts resist the wind load a building is designed for.

THE THREE ES-1 TEST METHODS

RE-1

Perimeter termination of mechanically attached or ballasted roof membranes.

RE-2

Pull-off resistance of metal fascia and edge flashing

RE-3

Pull-off resistance of metal wall coping, with upward and outward force applied together

GT-1

WHAT IS GT-1

​GT-1 is the test standard for external metal gutters. Its full name is ANSI/SPRI GT-1. ES-1 does not apply to gutters, so GT-1 fills that gap with three tests of wind and load resistance.

​

​

​

THE THREE GT-1 TEST METHODS

G-1

RE-1

G-2

Upward wind against the gutter bottom

G-3

Downward load on the gutter bottom from accumulated water and ice

DO BUILDING CODES REQUIRE ES-1 AND GT-1?

YES, FOR MOST LOW-SLOPE EDGE SYSTEMS UNDER THE INTERNATIONAL BUILDING CODE.

Edge Metal

The IBC calls for metal edge systems on built-up, modified bitumen and single-ply roofs below 2:12 slope to be designed for wind load and tested to ES-1. Gutters and counterflashing are excluded from that requirement.

Gutters

Gutters that secure the roof membrane's perimeter edge are covered separately, with testing under GT-1 methods G-1 and G-2. Editions and local amendments vary, so confirm the code in force with your code official.

Testing, not a brand

The code calls for testing. It does not specifically require UL certification, though a project specification may. NRCA's UL program is a credible, independent way to document it.

WHAT IS AN NRCA-AUTHORIZED FABRICATOR?

True Metal Supply is an NRCA-authorized fabricator. We fabricate specific copings, fascia, edge metal and external gutters for low-slope roofs in Knoxville, Tennessee, to the details in NRCA's UL certifications for ANSI/SPRI/FM 4435/ES-1 and ANSI/SPRI GT-1.

SPRI notes that copying a tested design does not make a product ES-1 tested. Being listed in a certification program is what connects a fabricator's work to the testing.

01

NRCA tests the details

NRCA conducted the ES-1 and GT-1 testing and holds the UL certifications.

02

The shop is authorized

True Metal Supply works under an agreement with the NRCA.

03

UL inspects the shop

Periodic UL inspections check our shop's ability to build to the certification.

04

Each length is labeled

A UL classification mark label goes on every covered piece.

UL Stickers

HOW DO YOU VERIFY A COVERED PIECE?

Look for the UL classification mark label. It is the only means of designating a piece as complying with NRCA's certification, and each covered length carries one.

Copings: white label

On the unexposed inside of the front face, near the center of the length.

Copings: white label

On the unexposed inside of the front face, near the center of the length.

Copings: white label

On the unexposed back side of the gutter, near the center of the length.